SW-1 Series
RATED VOLTAGE : 250V, ac (and 125V)RATED CURRENT : 10A (and 15A)INTERRUPTING CURRENT : 250V, ac 15ATRANSIENT OVERLOAD TEST CURRENT : dc current pulses, with an amplitude 150 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.
SW-2 SeriesRATED VOLTAGE : 250V, acRATED CURRENT : 2AINTERRUPTING CURRENT : 250V, ac 3ATRANSIENT OVERLOAD TEST CURRENT :dc current pulses, with an amplitude 30A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.
SW-3 Series
RATED VOLTAGE : 250V, acRATED CURRENT :15A INTERRUPTING CURRENT : 250V, ac 22.5ATRANSIENT OVERLOAD TEST CURRENT :dc current pulses, with an amplitude 225 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.
SW-5 Series
RATED VOLTAGE : 250V, ac (and 125V -*)RATED CURRENT : 5A (and 6A -*)INTERRUPTING CURRENT : 250V, ac 7.5ATRANSIENT OVERLOAD TEST CURRENT :dc current pulses, with an amplitude 75 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.
SW-6 Series
RATED VOLTAGE : 50V, dc RATED CURRENT : 2A or 4AINTERRUPTING CURRENT : 50V, dc 3A or 6A